Drying a structure correctly isn't about running a few fans and hoping — it's a calculated process based on temperature, humidity, and airflow readings.
We calculate air mover and dehumidifier placement using psychrometric formulas, not a flat per-room equipment count.

We calculate drying requirements using temperature and humidity data, not a flat per-room rule.
LGR capacity is standard equipment on every Structural Drying And Dehumidification job, not a premium upgrade.
Thermal scans on every Riverton, NJ job catch moisture a visual inspection alone would miss.
Moisture readings are logged daily throughout the Structural Drying And Dehumidification job so progress is measurable, not assumed.
Structural drying is a distinct phase with its own methodology, separate from initial extraction, and here's how our Riverton, NJ crews run it.

Psychrometric formulas determine exactly how much equipment capacity the space requires.
We map the full extent of moisture intrusion before placing a single air mover.
We position air movers to create directed airflow across wet surfaces based on the assessment.
Documented logs track the numbers from day one through final verification.
We adjust drying speed for sensitive materials like hardwood and cabinetry to prevent secondary damage.
Final verification compares closing readings against the material-specific dry standard, not a general guess.
We ask enough to bring the right instruments on the first visit.
A technician arrives with thermal imaging cameras and moisture meters ready to assess.
We complete the psychrometric assessment and thermal scan, then provide a written drying plan and quote.
We verify final moisture readings against dry standard before removing equipment.

"The thermal imaging found moisture behind a wall that looked completely fine from the outside. Would have missed it otherwise." — Julian R.
"They came back every single day to take readings and showed me the numbers improving. Felt like real science, not guesswork." — Monique T.
"Our hardwood floor didn't warp because they slowed the drying process down specifically for it." — Grant P.
Visual appearance doesn't confirm dryness — instrument readings are needed to catch what's not visible.
Psychrometrics uses scientific formulas to size the drying plan to the actual moisture load.
Typical drying time is 3-5 days for standard materials, longer for sensitive ones like hardwood.
We provide daily documented logs showing moisture readings, not just a verbal update.
Specialty drying protocols protect hardwood and cabinetry from the damage a standard drying speed could cause.
A stall in the daily logs triggers a plan review rather than simply leaving equipment running unchanged.
Riverton is within our core structural drying response zone.

Speak directly with our structural drying team.
Call +1-844-833-1325